All tubes are control grid modulated and also incorporate
a shadow grid to assist in the suppression of grid emission
and grid intercept current.
All L-3 Electron Devices' TWTs are inherently capable of
dual-stage collector depression should it be necessary to
fulfill a particular system requirement.
A mod anode connection is provided on all TWTs and may
be utilized to accommodate system sensing circuits and also
reduce the potential damage incurrred by cathode-to-anode
high-voltage arcs. This protection is accomplished through
the incorporation of an external anode-to-ground resistance
of two kilohms.
All cathode and collector voltages are referenced to ground.